Integrated Timeline
Explore cabin atmosphere, laboratory results and wearable physiology on one UTC mission clock. Each quantity keeps its own units; an association on this page is never evidence of cause.
Spacecraft context (selected mission)
Engineering status and mission checkpoints. Shown beside, never merged with, crew physiology.
- PowerNominal
- CommunicationsNominal
- Environmental control / life supportWatch
- Structure / subsystemsNominal
- TMI burnT+0.0 d · planned · Completed
- MCC-1T+15.0 d · planned · Completed
- MCC-2T+183.0 d · planned · Completed
- MCC-3T+335.0 d · planned · Upcoming
- MOIT+365.0 d · planned · Upcoming
Channels and time window
Cabin CO₂ is always shown. Daily-mean cabin resolution · wearable points are daily summaries (12:00 UTC) · blood samples at exact collection times.
Synchronized panels (physical units)
A-01 · D155 00:00Z → D185 00:00Z
Blue dotted lines = blood collection times (also marked on cabin and wearable panels). Amber dotted = exercise start (windows ≤ 14 d). Gray bands = no data recorded. Lines never bridge gaps; venous/unknown-type gas results and QC-flagged or rejected samples are plotted hollow and excluded from baselines and association statistics.
Cabin CO₂ vs blood pCO₂ — association
Preceding-24 h mean cabin CO₂ against reliable arterial/capillary blood pCO₂, one point per sample
Axes are auto-fitted and do not start at zero.
- Association, not causation. Both series drift over the mission, so a shared time trend can produce correlation on its own.
- Individual ventilation, exercise, sampling technique and sample type also influence blood pCO₂.
- Small n: use for exploration and hypothesis generation only.
Laboratory ↔ environment alignment
A-01 · 9 samples in window · cabin windows end at the exact collection timestamp
| Collected (UTC) | Type | Blood pCO₂ | Cabin CO₂ at hour | 24 h mean | 72 h mean | Resp. rate | SpO₂ | Exercise ≤6 h |
|---|---|---|---|---|---|---|---|---|
| 2031-11-09 08:47 | capillary | 40.9 | 4.57 | 4.43 (100%) | 4.52 (100%) | 14 | 97.7 | none |
| 2031-11-06 09:58 | venous | 44.5 | 4.60 | 4.51 (100%) | 4.61 (100%) | 15 | 97.0 | none |
| 2031-10-31 09:00 | capillary | 44.8 | 4.65 | 4.57 (100%) | 4.57 (100%) | 15 | 98.3 | none |
| 2031-10-28 07:41 | capillary | 42.4 | 4.56 | 4.35 (100%) | 4.24 (100%) | 14 | 97.8 | none |
| 2031-10-25 07:17 | arterial | 41.2 | 4.12 | 3.97 (100%) | 3.83 (100%) | 14 | 97.3 | none |
| 2031-10-23 10:27 | capillary | 39.6 | 3.92 | 3.72 (100%) | 3.54 (100%) | 15 | 98.0 | none |
| 2031-10-20 08:26 | capillary | 41.5 | 3.63 | 3.58 (100%) | 3.64 (100%) | 14 | 96.7 | none |
| 2031-10-17 10:50 | capillary | 41.9 | 3.98 | 3.68 (100%) | 3.71 (100%) | 14 | 97.5 | none |
| 2031-10-13 10:32 | capillary | 41.1 | 4.16 | 3.80 (100%) | 3.62 (100%) | 15 | 97.7 | none |
Cabin CO₂ in mmHg (ambient partial pressure); blood values in mmHg. Coverage = recorded hours ÷ hours in the window; below 75% is flagged and excluded from the association. Exercise within 6 h can transiently alter blood lactate and gases. Wearable columns are the daily summary for the sample's mission day.
Related: Environmental Monitoring · Wearables · Blood Gas Intelligence. Crew: A-01, A-02, A-03, A-04.