Mars Transit
Earth–Mars transfer · Mars · Mars transit · day 184 of 900 (2031-11-09 UTC)
These are three separate assessments: a healthy ship does not imply healthy crew.

- Crew ID
- NOX-CREW-0001
- Role
- Commander
- Mission
- NOX-01
- Age
- 46 y
- Height
- 182 cm
- Weight
- 84 kg
- NOX-01 · Commander active
Stable physiology; reference crew member.
- Resting heart rate58 bpm ▲ 0 bpm
- HRV (RMSSD)66 ms ▲ 3 ms
- SpO₂ (pulse oximetry)97.7 % ▲ 0.1 %
- Respiratory rate14 breaths/min ▲ 0 breaths/min
- Sleep duration7.1 h ▲ 0.0 h
- Skin temperature33.9 °C ▲ 0.4 °C
- Blood pressure117/77 mmHg
Wearable daily summaries, trend = 7-day mean · latest mission day 184 · ▲▼ versus first 14 days.
Cardiovascular, respiratory and blood (haematology) are analysed in this version.
Click any vessel or the heart. Drag to rotate, scroll to zoom.
- Arteries
- Veins
- Heart
Commander (A-01)
Demonstration data. Decision support for review; not a diagnosis.
- Astronaut
- Commander (A-01)
- Role
- Commander
- Mission
- NOX-01 · day 184
- Latest sample
- capillary, 2031-11-09 08:47 UTC
No measurement is clearly outside your own usual range.
Last blood sample: 2031-11-09 08:47 UTC.
| Analyte | Value | Unit | Collected | Quality |
|---|---|---|---|---|
| pH | 7.390 | 2031-11-09 08:47 UTC | QC clean | |
| pCO₂ | 40.9 | mmHg | 2031-11-09 08:47 UTC | QC clean |
| pO₂ | 90.0 | mmHg | 2031-11-09 08:47 UTC | Limited |
| cHCO₃⁻ | 24.5 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| BE | 0.0 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| Na⁺ | 139.0 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| K⁺ | 4.06 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| Cl⁻ | 104.0 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| Ca²⁺ | 1.22 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| Lac | 1.01 | mmol/L | 2031-11-09 08:47 UTC | QC clean |
| Glu | 80 | mg/dL | 2031-11-09 08:47 UTC | QC clean |
| tHb | 14.8 | g/dL | 2031-11-09 08:47 UTC | QC clean |
| Hct | 44.4 | % | 2031-11-09 08:47 UTC | QC clean |
| sO₂ | 97.2 | % | 2031-11-09 08:47 UTC | Limited |
| FO₂Hb | 95.9 | % | 2031-11-09 08:47 UTC | Limited |
| COHb | 0.7 | % | 2031-11-09 08:47 UTC | QC clean |
| MetHb | 0.6 | % | 2031-11-09 08:47 UTC | QC clean |
- Resting heart rate58 bpm
- HRV (RMSSD)66 ms
- Systolic BP117 mmHg
- Diastolic BP77 mmHg
- Respiratory rate14 breaths/min
- SpO₂ (pulse oximetry)97.7 %
- Sleep duration7.1 h
- Skin temperature33.9 °C
Symptom reports are stored separately and never change laboratory measurements.
- No symptoms documented.
No observation is waiting for review.
- Acid-base status within reference intervalsinfo · day 184
- What changed
- pH 7.390 · pCO₂ 40.9 mmHg · cHCO₃⁻ 24.5 mmol/L (before: pH 7.361 · pCO₂ 44.8 mmHg · cHCO₃⁻ 25.1 mmol/L (day 175)); baseline pH 7.399 · pCO₂ 40.0 (personal, first 10 samples)
- Why it matters
- No acid-base disorder pattern detected in this sample.
- How reliable
- Arterialized capillary sample. No QC flags raised. Sample: capillary.
- What needs review
- Pattern from a single sample, not a diagnosis. Acuity cannot be determined without history; compensation formulas are population estimates assuming steady state.
Not reviewed
Rules are deterministic and explainable. Nothing here is a diagnosis or a treatment or medication recommendation.
Spacecraft environment and engineering
NOX-01 · Mission dataset
- PowerNominal
- CommunicationsNominal
- Environmental control / life supportWatch
- Structure / subsystemsNominal
Cardiovascular: physiological measurements
Latest value per measurement for A-01 · mission NOX-01
- Heart rate (resting)Devicerecordedmission day 184 · Wearable device value (separate from analyzer results)58bpmDetail
- Heart rate (24 h mean)Devicerecordedmission day 184 · Wearable device value (separate from analyzer results)84bpmDetail
- Blood pressure, systolicDevicerecordedmission day 184 · Wearable device value (separate from analyzer results)117mmHgDetail
- Blood pressure, diastolicDevicerecordedmission day 184 · Wearable device value (separate from analyzer results)77mmHgDetail
- Hemoglobin (tHb)QC cleancapillaryrecorded2031-11-09 08:47 UTC · No QC flags raised.14.8g/dL—Detail
- HematocritQC cleancapillaryrecordedcalculated2031-11-09 08:47 UTC · No QC flags raised.44.4%—Detail
- LactateQC cleancapillaryrecorded2031-11-09 08:47 UTC · No QC flags raised.1.01mmol/L—Detail
- PotassiumQC cleancapillaryrecorded2031-11-09 08:47 UTC · No QC flags raised.4.06mmol/L—Detail
- Ionized calciumQC cleancapillaryrecorded2031-11-09 08:47 UTC · No QC flags raised.1.22mmol/L—Detail
Arterial and venous samples are not interchangeable: oxygenation values are interpreted only for arterial or capillary samples. Trends show only between comparable samples.
Clinical observations
Recent flagged items related to this system (last 14 mission days)
Nothing flagged for this system.
Devices and history · Cardiovascular
No device records for this astronaut and system.
Device records are not measurements. Wearable and CGM streams are shown only as wearable data, never as analyzer results.
No history recorded. Records are optional and none are assigned by default.
Manage records →Mission timeline and detailed modules
Open the full analytical pages for this mission.
- TMI burn T+0.0 d · Completed
- MCC-1 T+15.0 d · Completed
- MCC-2 T+183.0 d · Completed
- MCC-3 T+335.0 d · Upcoming
- MOI T+365.0 d · Upcoming