What NOX MED does
- In demo
Longitudinal blood gas monitoring
Every sample is kept on a true time scale, so each result is read against the mission so far, not on its own.
Open in demo → - In demo
Personalized physiological baselines
An astronaut's first ten reliable samples define a personal baseline. Later samples are scored against it with a z-score and a 30-day slope.
Open in demo → - In demo
Integrated wearable measurements
Resting heart rate, heart-rate variability, sleep and SpO₂ are compared with each astronaut's own early-mission baseline. Wearable SpO₂ is an estimate, not a blood measurement.
Open in demo → - In demo
Spacecraft environmental monitoring
Cabin CO₂, pressure and radiation dose rate are tracked beside crew data. They are never mixed with clinical values.
Open in demo → - In demo
Explainable clinical observations
Deterministic rules, no black box. Each observation shows the current and previous value, reference interval, baseline, the rule steps behind it, measurement validity and uncertainty.
Open in demo → - Planned
Astronaut self-assessment
A short structured check-in so the astronaut's own report sits beside the numbers. Not built yet.
- Prototype
Medical officer review
In the emergency simulator an observation can be acknowledged, a repeat sample requested, or the case escalated to the flight surgeon.
Open in demo → - Local-first
Offline-capable architecture
Analysis runs in the browser from local data. No server call is needed to interpret results, and imported records stay on the device. An installable offline mode is the next step.
Open in demo →
Blood gas intelligence
A single reading is a snapshot against a population range. An astronaut can drift away from their own normal while every value is still inside that range. Comparing each sample with the person's own history, its sample type and its quality flags shows the shift early, and shows when a value should not be trusted at all.
Below: a real output of the NOX MED rule engine for one fictional crew member. pCO₂ has risen about six standard deviations from that person's baseline while pH still sits inside its reference interval.
Each analyte opens its own trend in the demo.
Watchacid-basevalidity: validD184
Normal pH with isolated high pCO₂
- Current
- pH 7.356 · pCO₂ 45.3 mmHg · cHCO₃⁻ 25.1 mmol/L
- Previous
- pH 7.351 · pCO₂ 45.8 mmHg · cHCO₃⁻ 25.1 mmol/L (day 182)
- Reference interval
- pH 7.35–7.45 · pCO₂ 35–45 · HCO₃⁻ 22–26
- Personal baseline
- pH 7.407 · pCO₂ 39.5 (personal, first 10 samples)
Clinical significanceMinor deviation without pH change; monitor trend.
Why this observation- pH 7.356 vs 7.35–7.45: within interval.
- pCO₂ 45.3 vs 35–45 mmHg: high.
- HCO₃⁻ 25.1 vs 22–26 mmol/L: within interval (calculated).
- pCO₂ is 6.4σ above the personal baseline (trend).
UncertaintyPattern from a single sample, not a diagnosis. Acuity cannot be determined without history; compensation formulas are population estimates assuming steady state.
Space medicine relevance
- Respiratory acid–base abnormalities
pH, pCO₂ and HCO₃⁻ are classified into respiratory or metabolic patterns, with compensation checks.
- Ventilation assessment
pCO₂ trends are read alongside cabin CO₂, so a ventilation change can be separated from an environmental one.
- Oxygenation
pO₂ and sO₂ are interpreted only for arterial or arterialized samples. A venous pO₂ is never read as arterial oxygenation.
- Electrolyte disturbances
Sodium, potassium, chloride and ionized calcium are checked against reference intervals and the astronaut's own baseline.
- Physiological adaptation
Baseline drift in hemoglobin, hematocrit, lactate and glucose shows gradual change over months.
- Cardiovascular monitoring
Wearable resting heart rate, heart-rate variability and SpO₂, with potassium and ionized calcium as cardiac-relevant context.
- Environmental exposure monitoring
Cabin CO₂, pressure and radiation dose rate, plus carboxyhemoglobin and methemoglobin from the analyzer.
Future development: bone loss, immune dysregulation and neuro-ocular conditions need other measurements. Blood gas analysis does not diagnose them, and NOX MED does not claim to.
References and data
Integrated in this softwareNo NASA or OSDR datasets are loaded. Every crew, laboratory, wearable and cabin record in the demo is fictional, generated by project scripts and labelled by origin. The references above are background reading, not validation.
Research prototype for decision support. Thresholds are illustrative and not clinically validated. Not FDA- or NASA-certified, no treatment recommendations, no disease prediction. Data sources & methods